Pepperl+Fuchs KFD2 serisi
Katalogda Pepperl+Fuchs KFD2 serisinden 83 kalem bulunuyor (Switch Amplifier, SMART Transmitter Power Supply, Solenoid Driver, Voltage Repeater). Aşağıdaki tablo aynı ailedeki varyantları yan yana koyar; satırlar kalemin kendi teknik verisinden gelir.
Bu serinin kategorileri
KFD2 varyantlarısayfa 1/2
| Parça kodu | Connection | Rated voltage | Signal type | Connection side |
|---|---|---|---|---|
| KFD2-BR-1.PA.1500 | Power Rail or terminals 11 (L+), 12 (L-) | U r 20 ... 30 V DC | — | — |
| KFD2-BR-Ex1.3PA.93 | Power Rail or terminals 59+, 60-, 58 FE | U r 20 ... 35 V DC | — | — |
| KFD2-CRG2-1.D | Power Rail or terminals 23+, 24- | U r 20 ... 30 V DC | Analog input | field side |
| KFD2-CRG2-Ex1.D | Power Rail or terminals 23+, 24- | U r 20 ... 30 V DC | Analog input | field side |
| KFD2-DWB-1.D | terminals 23+, 24- or power feed module/Power Rail | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-DWB-Ex1.D | terminals 23+, 24- or power feed module/Power Rail | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-EB2 | terminals 11+, 12- terminals 8+, 9- | U r 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. | — | — |
| KFD2-EB2.R4A.B | terminals 11+, 12- terminals 8+, 9- | U r 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. | — | — |
| KFD2-EB2.R4A.B.SP | terminals 11+, 12- terminals 8+, 9- | U r 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. | — | — |
| KFD2-EB2.SP | terminals 11+, 12- terminals 8+, 9- | U r 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. | — | — |
| KFD2-ER-1.W.LB | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-ER-2.W.LB | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-ER-Ex1.W.LB | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-GS-1.2W | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Analog input | field side |
| KFD2-GUT-1.D | terminals 23+, 24- or power feed module/Power Rail | U r 20 ... 30 V DC | Analog input | field side |
| KFD2-GUT-Ex1.D | terminals 23+, 24- or power feed module/Power Rail | U r 20 ... 30 V DC | Analog input | field side |
| KFD2-HLC-Ex1.D | Power Rail or terminals 23+, 24- | U r 19 ... 30 V DC | Analog input | field side |
| KFD2-HLC-Ex1.D.2W | Power Rail or terminals 23+, 24- | U r 19 ... 30 V DC | Analog input | field side |
| KFD2-HMM-16 | terminals 17+, 18- | U r 20 ... 32 V DC typical at 100 mA | — | — |
| KFD2-PT2-Ex1 | Power Rail or terminals 11+, 12- | U r 20 ... 35 V DC | Analog input | field side |
| KFD2-PT2-Ex1-1 | Power Rail or terminals 11+, 12- | U r 20 ... 35 V DC | Analog input | field side |
| KFD2-PT2-Ex1-5 | Power Rail or terminals 11+, 12- | U r 20 ... 35 V DC | Analog input | field side |
| KFD2-RCI-1 | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Output | control side |
| KFD2-RSH-1.2D.FL2 | Power Rail or terminals 14+, 15- | U r 19 ... 26.4 V DC | Digital Output | control side |
| KFD2-RSH-1.2D.FL3 | Power Rail or terminals 14+, 15- | U r 19 ... 26.4 V DC | Digital Output | control side |
| KFD2-RSH-1.2E.L2 | Power Rail or terminals 14+, 15- | U r 19 ... 26.4 V DC | Digital Output | control side |
| KFD2-RSH-1.2E.L3 | Power Rail or terminals 14+, 15- | U r 19 ... 26.4 V DC | Digital Output | control side |
| KFD2-SCD2-Ex1.LK | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Analog output | control side |
| KFD2-SCD2-Ex2.LK | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Analog output | control side |
| KFD2-SH-Ex1 | Power Rail or terminals 22+, 23+, 24- | U r 20 ... 35 V DC | Digital Input | field side |
| KFD2-SH-Ex1.T.OP | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-SL-4 | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Output | control side |
| KFD2-SL2-Ex2 | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Output | control side |
| KFD2-SL2-Ex2.B | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Output | control side |
| KFD2-SLD-Ex1.13100 | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC loop powered | Digital Output | control side |
| KFD2-SLD-Ex2.1045-Y1 | Power Rail or terminals 14+, 15- | U r 18 ... 30 V DC | Digital Output | control side |
| KFD2-SLD-Ex2.1245-Y1 | Power Rail or terminals 14+, 15- | U r 18 ... 30 V DC | Digital Output | control side |
| KFD2-SLD-Ex2.1545-Y1 | Power Rail or terminals 14+, 15- | U r 18 ... 30 V DC | Digital Output | control side |
| KFD2-SOT3-Ex1.LB | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SOT3-Ex1.LB.IO | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SOT3-Ex2 | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SOT3-Ex2.IO | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SOT3-Ex2.IO-Y1 | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SR2-2.2S | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-SR2-2.W.SM | terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-SR2-Ex1.W.LB | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SR2-Ex2.2S | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-SR2-Ex2.W | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SR2-Ex2.W.SM | Power Rail or terminals 14+, 15- | U r 20 ... 30 V DC | Digital Input | field side |
| KFD2-SR3-2.2S | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SR3-Ex2.2S | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-SRA-Ex4 | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-ST3-Ex1.LB | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-ST3-Ex2 | Power Rail or terminals 14+, 15- | U r 19 ... 30 V DC | Digital Input | field side |
| KFD2-STC4-Ex1 | Power Rail or terminals 14+, 15- | U r 20 ... 35 V DC | Analog input | field side |
| KFD2-STC5-1 | Power Rail or terminals 14+, 15- | U r 18 ... 30 V DC | Analog input | field side |
| KFD2-STC5-1.2O | Power Rail or terminals 14+, 15- | U r 18 ... 30 V DC | Analog input | field side |
| KFD2-STC5-2 | Power Rail or terminals 14+, 15- | U r 18 ... 30 V DC | Analog input | field side |
| KFD2-STC5-Ex1 | Power Rail or terminals 14+, 15- | U r 18 ... 30 V DC | Analog input | field side |
Teknik verisi yüklenmemiş kalemler
Pepperl+Fuchs markasının yakın serileri
Pepperl+Fuchs kataloğunun tamamı için Pepperl+Fuchs marka sayfası, fiyat ve tedarik süresi için teklif formu.